1. Far-UVC Purchasing Portal Buy From Far UV Light Manufacturers Direct
  2. Far UVC Lamp Manufacturers
  3. 222nm KrCl Excimer Bulbs
  4. Far UVC Tube Lamps
  5. First UVC 222nm 15-Watt Far UVC Excimer Lamp

First UVC 222nm 15-Watt Far UVC Excimer Lamp

First UVC 222nm 15-Watt Far UVC Excimer Lamp
Brand: First-UVC
Category: Far UVC Tube Lamps


  • Power output

Each 15-Watt Excimer Bulb is hand-assembled and manufactured in an official ISO9001 Excimer Far-UV Light Factory (quality management systems) delivered by the Agency for International Standardization. To provide the highest-quality Far-UV light products globally, a battery of testing that includes but is not limited to: Microbiological Effectiveness Test, IEC62471 (photobiological safety inspection), BACL ( 222m, wavelength test), and CE, FCC, RoHS Certifications. When you need a 15W Far-UV light bulb, make sure your Far UVC choice is always QuantaDose for the best Far-UVC lighting to meets your AP-UVGI needs.

First UVC Bulb 15-Watt Far UVC Excimer Bulb 222nm Far-UVC F-Series Far UVC 15w Far-UV Light 24V DC

CAUTION: Far-UVC sources have not been tested for photosensitive individuals or those exposed to photo-sensitizing agents.
CAUTION: Far-UVC may help to reduce the number of germs and microbes, but it will not eliminate them.
NOTE: Far-UVC is designed to sanitize air and surfaces using far ultraviolet C (Far-UVC). Research has shown Far-UVC light to be as or more effective in inactivating microbes than UVC light. Unlike conventional UVC, Far-UVC does not require the use of UV protective equipment when UVC wavelengths greater than 230nm are filtered from the Far-UVC light source. [1] [2] [3]
NOTE: The actual inactivation rate of microbes on surfaces and air will vary based on the type of microorganisms and the length of exposure time irradiated.
NOTE: QuantaDose issued a press release that offers an easy spreadsheet calculator tool to help Far-UVC light designers determine time allowance with a known power and distance to help figure out the time necessary to be effective and when the maximum levels of safe 222nm exposure levels are reached under current international standards. USA 22 mJ/cm2 EU 30 mJ/cm2

Download it here Excel Doc. (Far-uvc-light-222nm-irradiance-time-distance-power-calculation-tool)

NOTE: Far-UVC is to be used combined with all safety measures and is not intended as a replacement or modification to an existing cleaning and sanitization program.
NOTE: Far-UVC a KrCl emitter has a nominal operational life of >3000 hours.   If the visible dim violet glow is no longer detected, the Far-UVC lamp must be replaced.  A QuantaDose UVC test card is recommended for Far-UVC light testing as well.

Far-UV Light Specs

Main Specifications

Lamp Technology Lamp Technology Excimer
UV Spectrum UV Spectrum Far-UVC
Peak wavelength(nm) Peak wavelength(nm) 222nm
Total Watts Total Watts 15-watts
Lamp Gas Mixture Lamp Gas Mixture KrCl
Expected Lifespan Expected Lifespan 4000+ Hours
Dimensions Dimensions D.19*160mm
Mercury Free Lamp Mercury Free Lamp Yes
Beam Angle Beam Angle 360
Ambient Operating Temp Range Ambient Operating Temp Range 20℃ to 50℃
Input Voltage Input Voltage 24V
Input Current Input Current DC
Certification Certification CE, FCC, RoHS
Electrical Connectors Included Electrical Connectors Included
End Caps End Caps Polymer
Instant-On Lamp, No Warm-Up Time Instant-On Lamp, No Warm-Up Time
Warranty Warranty 12 Month

Far-UVC Output Power

UV Spectrum UV Spectrum Far-UVC
0cm Far-UV Power µW/cm² 0cm Far-UV Power µW/cm² 2800
10cm Far-UV Power µW/cm² 10cm Far-UV Power µW/cm² 630
100cm Far-UV Power µW/cm² 100cm Far-UV Power µW/cm² 28
150cm Far-UV Power µW/cm² 150cm Far-UV Power µW/cm² 3
200cm Far-UV Power µW/cm² 200cm Far-UV Power µW/cm² 1.5
250cm Far-UV Power µW/cm² 250cm Far-UV Power µW/cm² 1

Time To Reach 6 mJ/cm2 Germicidal Dose

UVGI Dosage Time @ 0cm UVGI Dosage Time @ 0cm 2.0 Sec 0.0 Min
UVGI Dosage Time @ 10cm UVGI Dosage Time @ 10cm 37.5 Sec 0.6 Min
UVGI Dosage Time @ 50cm UVGI Dosage Time @ 50cm 93.8 Sec 1.6 Min
UVGI Dosage Time @ 100cm UVGI Dosage Time @ 100cm 285.7 Sec 4.8 Min
UVGI Dosage Time @ 150cm UVGI Dosage Time @ 150cm 3000.0 Sec 50.0 Min
UVGI Dosage Time @ 200cm UVGI Dosage Time @ 200cm 6000.0 Sec 100.0 Min
UVGI Dosage Time @ 250cm UVGI Dosage Time @ 250cm 7500.0 Sec 125.0 Min

Time To Reach 22 mJ/cm2 (Under ICNIRP Limit)

Time Limit Distance 0cm Time Limit Distance 0cm 7.9 Sec 0.1 Min
Time Limit Distance 10cm Time Limit Distance 10cm 34.9 Sec 0.6 Min
Time Limit Distance 50cm Time Limit Distance 50cm 314.3 Sec 5.2 Min
Time Limit Distance 100cm Time Limit Distance 100cm 785.7 Sec 13.1 Min
Time Limit Distance 150cm Time Limit Distance 150cm 7333.3 Sec 122.2 Min
Time Limit Distance 200cm Time Limit Distance 200cm 14666.7 Sec 244.4 Min
Time Limit Distance 250cm Time Limit Distance 250cm 22000.0 Sec 366.7 Min

Time To Reach Purportedly Safe Levels 500 mJ/cm2 (Peer reviewed)

Purported Time Limit Distance 0cm Purported Safe Time (Filtered Only ) 166.7 Sec 2.8 Min
Purported Time Limit Distance 10cm Purported Time Limit Distance 10cm 3125.0 Sec 52.1 Min
Purported Time Limit Distance 50cm Purported Time Limit Distance 50cm 7812.5 Sec 130.2 Min
Purported Time Limit Distance 100cm Purported Time Limit Distance 100cm 28809.5 Sec 396.8 Min
Purported Time Limit Distance 150cm Purported Time Limit Distance 150cm 250000.0 Sec 4166.7 Min
Purported Time Limit Distance 200cm Purported Time Limit Distance 200cm 500000.0 Sec 8333.3 Min
Purported Time Limit Distance 250cm Purported Time Limit Distance 250cm 625000.7 Sec 10416.7 Min